PCB circuit board exhaust gas treatment spray tower pump application case

  Printed circuit board (PCB) industry belongs to the heavy pollution industry, in the production process, there will be the generation of waste gas, which will contain chromium exhaust, cyanide exhaust (small amount), acid mist and so on. The chromic acid mist generated in the chromium plating process is highly toxic. Generally, acid and alkali neutralisation is used for waste gas treatment. Shower tower is a common equipment in the gas-liquid reaction system, exhaust gas and liquid reverse contact, after washing to make the gas to achieve purification, dust removal, cooling, etc., exhaust gas treatment shower tower pump is now widely used in PCB circuit board acid and alkali waste gas treatment.

  PCB circuit board waste gas spray tower pump parameters

  Pump supporting: PCB circuit board waste gas treatment spray washing tower

  Project Customer: Guangzhou PCB circuit board factory

  Actual flow: 35m3/h

  Actual head: 6m

  Water body analysis: acid and alkali neutralisation liquid (PH: 9)

  Water temperature: 35℃

  Application process: acid and alkali neutralisation liquid spraying, circulation

  Customer requirements: continuous idling, installed outside the tank with rain cover

  Medium concentration: thirty-five per cent sodium hydroxide

  Exhaust gas treatment spray tower workflow

  Line board waste gas treatment spray tower pump selection

  1, confirm the pump type

  According to the customer site process to determine the type of water pump: customers need to use the pump in the acid and alkali neutralisation liquid spray, circulation, first we can determine the Division I can use the pump: Mabel MK acid and alkali self-priming pumps, MIT acid and alkali tank vertical pumps, MD acid and alkali tank vertical pumps as well as MZ acid and alkali centrifugal pumps.

  2、Determine the pump material

  According to the type of media, temperature, concentration to determine the pump material: customer site water is mainly: acid and alkali neutral liquid (PH: 9); temperature of 35 ℃ room temperature, the main medium for thirty-five per cent of sodium hydroxide.

  According to the medium of PH acidity and alkalinity, temperature and concentration, we recommend the customer pump material selection: FRPP.

  3, determine the pump power

  According to the actual head flow to determine the power of the pump: the customer needs the actual head of the pump 6M, the actual capacity of 35m³/h, so we recommend the appropriate pump power: 3.75KW.

  4、Determine the specific model

  Determine the specific model according to the customer's other requirements: the customer requires the pump to achieve sustainable idling, vertical installation outside the tank with rain cover requirements. Combined with the material, power, process, we recommend to customers: MD acid and alkali vertical pump. Specific model: MD-65VK-55NF, material: FRPP, power: 3.75KW.