Electroplating project cyanide-containing plating rinsing wastewater treatment pump application case

  A plating project wastewater treatment pump parameters

  Pump Matching:Electroplating with cyanide rinsing wastewater treatment project

  Project Customer: An electroplating company in Changzhou

  Actual flow: 25m3/h

  Actual head: 8m

  Water analysis: cyanide wastewater & acidic wastewater(PH:2)

  Temperature of water body:60℃

  Application process: cyanide plating wastewater acid and alkali transport dosing

  Customer requirements: pumps can be idle, horizontal ground installation

  Medium concentration: 60 per cent hexavalent chromic acid

  Characteristics of electroplating wastewater.

  The composition of electroplating wastewater is very complex, in addition to cyanide-containing (CN-) wastewater and acid-alkali wastewater, heavy metal wastewater is a potentially hazardous wastewater category in the electroplating industry. According to the classification of heavy metal wastewater containing heavy metal elements, it can generally be divided into wastewater containing chromium (Cr), nickel (Ni), cadmium (Cd) wastewater, copper (Cu), zinc (Zn), gold (Au), silver (Ag) and other wastewater. If the wastewater is discharged into the natural water body, it will cause serious pollution to the ecological environment, and can threaten the human health, triggering the consequences of carcinogenicity, teratogenicity and mutation.

/uploads/allimg/20231103/1-231103112035644.jpg

  Cyanide plating wastewater treatment pump selection

  1, confirm the type of pump

  Customers need to use the pump in the cyanide plating wastewater acid and alkali transport dosing, first of all, we can determine our pumps can be used: Mabel MK acid and alkali self-priming pumps, MC acid and alkali chemical pumps, MD acid and alkali vertical pumps, MS acid and alkali magnetic pumps, as well as MZ acid and alkali centrifugal pumps.

  2、Determine the pump material

  According to the type of medium, temperature, concentration to determine the pump material: customer cyanide plating wastewater water body is mainly: cyanide wastewater & acidic wastewater (PH: 3.5-5); temperature of 60 ℃, the main medium for the sixty per cent of hexavalent chromic acid.

  According to the PH acidity and alkalinity of the medium, temperature and concentration, we recommend the customer pump material selection: PVDF Teflon material.

  3、Determine the power of the pump

  According to the actual head flow rate to determine the power of the pump: the customer needs the actual head of the pump 8M, the actual capacity of 25m³/h, so we recommend the pump power: 3.75KW.

  4、Determine the specific model

  Determine the specific model according to the customer's other requirements: the customer requires the pump to reach the idle, horizontal ground installation, corrosion resistance requirements. Combined with the material, power, process, we recommend to the customer: can be idle acid and alkali self-priming pump. Specific model: MKP-50052VBH-SSH, material: PVDF, power: 3.75KW.

  Recommended pumps for rinsing wastewater treatment of cyanide-containing plated layer

Corrosion-resistant self-priming pumps

Self-priming pumps for wastewater treatment

Small magnetic drive pumps

Magnetic pumps for wastewater treatment

vortex type chemical centrifugal pump

Wastewater treatment chemical pumps