What details do I need to pay attention to when using a corrosion-resistant magnetic drive pump?

Views :
Update time : 2023-10-26

  Many people want to know, Mabel environmental protection production of magnetic pumps in the use of what small common sense, that small first take you to understand, what is a magnetic pump, magnetic pump (also known as magnetic drive pump) is mainly composed of a pump head, magnetic drive (magnetic cylinder), motor, base and other parts of the parts.

magnetic pump without shaft seal(无轴封磁力泵).jpg

  Magnetic pump magnetic drive consists of outer magnetic rotor, inner magnetic rotor and non-conductive isolation sleeve. When the motor drives the outer magnetic rotor to rotate through the coupling, the magnetic field can penetrate the air gap and the non-magnetic material isolation sleeve, and drive the inner magnetic rotor connected with the impeller to rotate synchronously, so as to realise the contactless synchronous transmission of power, and to transform the dynamic sealing structure which is easy to be leaked into the static sealing structure which has zero leakage. Due to the pump shaft, the inner magnetic rotor is completely closed by the pump body and isolation sleeve, thus completely solving the problem of "running, risking, dripping and leaking".

  As can be seen from the above, the magnetic pump can be said to be an excellent representative of the pump, solve a lot of industry problems, so that the production goes smoothly, and now I'll take you to learn more about the daily use of some of the precautions of the Mabel magnetic pump.

  First, the magnetic pump due to cavitation

  Pump cavitation is mainly due to the pump inlet pipe resistance, more gas phase of the transport medium, filling the pump is not sufficient, the pump inlet energy head is not enough and other reasons. Cavitation is very harmful to the pump, cavitation occurs when the pump vibrates violently, the balance is seriously damaged, will lead to pump bearings, rotor or impeller damage. This is a common cause of magnetic pump failure.

  Second, no medium or small flow rate of the transport medium

  So that the rotor spindle and the stability of the bearing dry friction, burned bearing. Magnetic pumps are lubricated and cooled by the delivery medium to the sliding bearings, in the absence of open inlet or outlet valves, the sliding bearings due to the absence of delivery medium lubrication and cooling and lead to high temperature and thus damage.

  Third, to prevent particles from entering

  1. Do not allow ferromagnetic impurities, particles into the magnetic actuator and bearing friction vice situation.

  2. After conveying the medium that is easy to crystallise or precipitate, it should be flushed in time (fill the pump cavity with water after stopping the pump and discharge it cleanly after running for 1min) in order to guarantee the service life of the sliding bearings.

  3. When conveying the medium containing solid particles, it should be filtered at the entrance of the pump flow pipe.

  Fourth, the isolation sleeve damage

  Magnetic pump magnetic coupling is cooled by the pump conveying medium, if the medium has hard particles, it is easy to cause the isolation sleeve scratched or scratched through, sometimes if the maintenance method is not appropriate may also cause damage to the isolation sleeve.

  V. Prevent dry friction

  1. Idle rotation is strictly prohibited.

  2. Strictly prohibit the media pumping.

  3. In the case of the outlet valve is closed, the pump continuous running time shall not exceed 2min, in order to prevent the magnetic actuator overheating and failure.

  Prevent demagnetisation

  1. The magnetic torque should not be designed too small.

  2. It should be operated under the specified temperature conditions, and it is strictly prohibited for the medium temperature to exceed the standard. Magnetic pump isolation sleeve can be installed on the outer surface of the platinum resistance temperature sensor to detect the temperature rise in the ring gap region, so that the temperature exceeds the limit of the alarm or shutdown.

Contact MEIBAO
Tel
+86-13922943272

Send your message to us

Related News
Plastic plating filter for stationery processing plant
Plastic plating filter for stationery processing plant
07 .17.2024
 In the vibrant land of Xuzhou, a stationery processing plant is bringing unprecedented innovation ...
How to select a submerged pump
How to select a submerged pump
10 .25.2023
 Selection method of submerged pump  The traditional submerged pump is suitable for conveying any c...
What causes exhaust tower vertical pumps to leak?
What causes exhaust tower vertical pumps to leak?
10 .25.2023
 Shower tower vertical pump because it is corrosion-resistant, can be idle, easy to install, small ...
What pumps are used for hydrogen peroxide transfer?
What pumps are used for hydrogen peroxide transfer?
08 .21.2024
 Hydrogen peroxide, as a commonly used oxidizing agent, is increasingly used in industry and enviro...
Related Products
vertical pump in circular plate tank
vertical pump in circular plate tank
  • Head:0-19m
  • Voltage:220V/380V
  • Material:PPH, PVDF
  • Flow rate:0-440L/min
  • Pump Power:1-3HP
aluminum alloy penumatic diaphragm pump
aluminum alloy penumatic diaphragm pump
  • Head:84 m
  • Voltage:220V/380V
  • Material:Alufer
  • Flow rate:0-1060L/min
vertical pump in square plate tank
vertical pump in square plate tank
  • Head:0-19m
  • Voltage:220V/380V
  • Material:PPH, PVDF
  • Flow rate:0-440L/min
  • Pump Power:1-3HP
Small magnetic drive pumps
Small magnetic drive pumps
  • Head:0-11.6m
  • Voltage:220V/380V
  • Material:GFRPP, CFRPP, PVDF, ETFE
  • Flow rate:1-130L/min
  • Pump Power:45-260w